North Texas Foundation Field Manual logo — a slab and pier in section inside a drawing title blockNorth Texas Foundation Field ManualSoils, slabs, evaluation and repair in Dallas-Fort Worth
EntityMap v1.0

North Texas Foundation Field Manual Entity Map

This is the machine-readable knowledge map for North Texas Foundation Field Manual, published to the EntityMap v1.0 specification. It describes the site's key entities — the 17 sheets of the manual, the standards and sources they depend on, and the categories and families that organize them — with evidence passages drawn from its pages and links to the open knowledge graph.

View the EntityMap JSON → (40 entities · EntityMap v1.0)

Thing

Expansive Clay and the Blackland Prairie

Much of the Metroplex sits on smectite-rich clays that swell when wet and shrink when dry. Every other sheet starts here.

Relations:

  • PART_OF → Soils and site

Expansive clay is soil that changes volume as its moisture changes. It swells when it takes on water and shrinks as it dries. The cause is mineralogy: the U.S. Natural Resources Conservation Service explains that Vertisols such as Houston Black contain smectite, a clay mineral that swells markedly when moist and shrinks when dry. Houston Black is the best-known example.

Expansive Clay and the Blackland Prairie | North Texas Foundation Field Manual — published by North Texas Foundation Field Manual
Thing

Plasticity Index (PI)

The spread between a clay's liquid and plastic limits. Higher PI generally means more shrink and swell.

Relations:

  • PART_OF → Soils and site

The plasticity index, or PI, is a laboratory value that describes how a fine-grained soil behaves as its water content changes. It comes from the Atterberg limits. The liquid limit is the water content at which a soil starts to flow like a liquid; the plastic limit is the water content at which it stops being moldable and begins to crumble. The plasticity index is the difference between the two. A soil with a wide range between those limits stays plastic over a broad span of moisture.

Plasticity Index (PI) | North Texas Foundation Field Manual — published by North Texas Foundation Field Manual
Thing

Potential Vertical Rise (PVR)

TxDOT's Tex-124-E estimate built from PI. Useful in design, easily misread as a prediction.

Relations:

  • PART_OF → Soils and site

Potential vertical rise, or PVR, is an engineering estimate of how much an expansive soil column could swell upward if it took on water. The Texas Department of Transportation's test method for it is Tex-124-E, "Determining Potential Vertical Rise." University of Texas at Austin training material explains that Tex-124-E is a modified version of McDowell's 1959 method and is based on correlations between the plasticity index and swelling. TxDOT's pavement manual recommends analyzing a 15-foot soil column.

Potential Vertical Rise (PVR) | North Texas Foundation Field Manual — published by North Texas Foundation Field Manual
Thing

Trees and Soil Moisture

Large trees near a foundation can shrink clay on one side. Removal can cause heave; the guidelines urge caution.

Relations:

  • PART_OF → Soils and site

Trees and large shrubs pull water from the soil through their roots. On expansive clay, removing water shrinks the soil. When the tree stands near a foundation, the soil beneath the nearest part of the house can dry and settle more than the rest, producing differential movement. The Texas Real Estate Commission lists tree roots and large plants near the foundation among the factors that can affect foundation performance.

Trees and Soil Moisture | North Texas Foundation Field Manual — published by North Texas Foundation Field Manual
Thing

Grading and Drainage

ASCE Texas Section guidance calls for a 5 percent slope for the first 10 feet where practicable.

Relations:

  • PART_OF → Soils and site

Grading is the shape of the ground around a house. Drainage is how water leaves it. Together they decide whether rain and irrigation water run away from the foundation or collect against it. On expansive clay, water that ponds along one side of a house wets the soil there more than elsewhere, and the foundation can move unevenly as a result. ASCE Texas Section guidance calls for a 5 percent slope for the first 10 feet where practicable.

Grading and Drainage | North Texas Foundation Field Manual — published by North Texas Foundation Field Manual
Thing

Post-Tensioned Slab Foundations

The common North Texas slab. Its tendons are under high tension, so cutting or coring needs locating them first.

Relations:

  • PART_OF → Foundation types

A post-tensioned slab is a concrete foundation reinforced with high-strength steel tendons. The tendons are laid in plastic sheathing, the concrete is poured around them, and after the concrete gains strength the tendons are pulled tight with hydraulic jacks and anchored at the slab edges. The tension compresses the concrete, which helps it resist cracking and bending.

Post-Tensioned Slab Foundations | North Texas Foundation Field Manual — published by North Texas Foundation Field Manual
Thing

Conventionally Reinforced Slab Foundations

Designed under different rules from post-tensioned slabs. Older and some custom DFW houses use them.

Relations:

  • PART_OF → Foundation types

A conventionally reinforced slab is a concrete foundation whose steel reinforcement is placed but not stressed. The steel may be deformed reinforcing bars, called rebar, or welded wire fabric. The reinforcement carries tension that concrete alone cannot, and thickened beams around the perimeter and across the slab add stiffness. Before post-tensioning became the common residential choice in Texas, many slabs were built this way, and some builders and engineers still specify conventional reinforcement for particular projects.

Conventionally Reinforced Slab Foundations | North Texas Foundation Field Manual — published by North Texas Foundation Field Manual
Thing

Pier and Beam Foundations

Common in older Dallas and Fort Worth neighborhoods. Shims, framing and crawl space moisture are the usual questions.

Relations:

  • PART_OF → Foundation types

A pier and beam foundation holds the house above the ground. Piers, often concrete, bear on the soil or extend into it; beams span between them; floor joists and subfloor sit on the beams. The space beneath is a crawl space, sometimes accessible through a hatch or an exterior opening. Perimeter walls or skirting enclose it. Because the floor is framed rather than poured, a pier and beam house can be releveled by adjusting supports, and plumbing and wiring under the floor are reachable. Those are real advantages on moving clay.

Pier and Beam Foundations | North Texas Foundation Field Manual — published by North Texas Foundation Field Manual
Thing

The Inspector's Foundation Opinion

A Texas inspector must state whether the foundation is performing. Cause and repair belong to an engineer.

Relations:

  • PART_OF → Evaluation

Under the Texas Real Estate Commission's standards of practice, 22 TAC 535.228(a), an inspector shall render a written opinion as to the performance of the foundation. The inspector must report the type of foundation and, for a crawl space, the vantage point from which it was inspected, and must generally report present and visible indications used to render the opinion of adverse performance.

The Inspector's Foundation Opinion | North Texas Foundation Field Manual — published by North Texas Foundation Field Manual
Thing

Engineering Investigation Levels A, B and C

ASCE Texas Section defines three levels, from a walk-through to testing. A letter should say which it is.

Relations:

  • PART_OF → Evaluation

The Texas Section of the American Society of Civil Engineers publishes Guidelines for the Evaluation and Repair of Residential Foundations. Version 1 was adopted in 2002, Version 2 in 2009, and Version 3 in April 2022. The guidelines are written for engineers and are voluntary; they say plainly that they are not a standard of care. But they give buyers a useful vocabulary, especially the three levels of investigation. Level A is a report of first impressions, based on an interview, a review of available documents, and a walk-through.

Engineering Investigation Levels A, B and C | North Texas Foundation Field Manual — published by North Texas Foundation Field Manual
Thing

Floor Elevation Surveys

Measures differences, not causes. Outside a standard Texas inspection, and built-in unevenness muddies it.

Relations:

  • PART_OF → Evaluation

A floor elevation survey records the relative height of points across a floor, usually on a grid or at room centers and corners, using a manometer-style water level, a digital leveling instrument or a laser. The result is a set of numbers, often drawn as a plan with contour lines, showing which parts of the foundation are higher or lower than a reference point. In the ASCE Texas Section guidelines, an elevation survey and a scaled drawing of the readings are what distinguish a Level B engineering investigation from a Level A walk-through.

Floor Elevation Surveys | North Texas Foundation Field Manual — published by North Texas Foundation Field Manual
Thing

Deflection and Tilt Criteria

The engineers' yardsticks for judging measured movement. Context and symptoms still decide.

Relations:

  • PART_OF → Evaluation

Deflection describes how much a foundation bends. The ASCE Texas Section guidelines define the deflection ratio as the maximum deviation of a point from a straight line drawn between two other points, divided by the distance between them, written as a fraction of L, the span. Tilt describes how much the foundation leans overall, expressed as a percentage: the difference in elevation over the distance. The engineers' yardsticks for judging measured movement. Context and symptoms still decide.

Deflection and Tilt Criteria | North Texas Foundation Field Manual — published by North Texas Foundation Field Manual
Thing

Distress Indicators

The visible signs inspectors report. Each has other causes, and some movement is normal on clay.

Relations:

  • PART_OF → Evaluation

A distress indicator is a visible condition in a house that can result from foundation movement. TREC's 2025 guidance to inspectors lists the common ones: doors that bind, fail to latch or are out of square; separations in framing or frieze boards; sloping floors; cracks or separations in walls, ceilings or floors; and buckling or cracking of masonry cladding. The standards of practice add retaining wall deficiencies related to foundation performance, exposed or damaged reinforcement, and crawl space ventilation and drainage that are not performing.

Distress Indicators | North Texas Foundation Field Manual — published by North Texas Foundation Field Manual
Thing

Underpinning Piles and Piers

The common slab repair. It supports the foundation where installed; it does not promise a level floor.

Relations:

  • PART_OF → Repair and records

Underpinning places supports under an existing foundation to carry its load down to soil that is less affected by seasonal moisture change. On slab foundations, a contractor excavates beside or beneath the grade beam, installs the pile or pier, and transfers the foundation's weight onto it, often lifting the slab in the process. The ASCE Texas Section guidelines list underpinning first among slab remedial measures. The common slab repair. It supports the foundation where installed; it does not promise a level floor.

Underpinning Piles and Piers | North Texas Foundation Field Manual — published by North Texas Foundation Field Manual
Thing

Grouting, Crack Injection and Tendon Stressing

Mudjacking, epoxy injection and restressing each answer a different problem, and some conflict with piers.

Relations:

  • PART_OF → Repair and records

The ASCE Texas Section guidelines list several slab remedial measures besides underpinning: grouting, mudjacking, crack injecting, tendon stressing, and partial demolition and reconstruction. Each addresses something different. Grouting and mudjacking pump a material beneath a slab through drilled holes. The goal may be to fill voids left by soil loss or erosion, or to raise a sunken area. A manufacturer's comparison of repair options describes slab jacking as drilling or coring holes and pumping fluid under pressure to float or raise the slab.

Grouting, Crack Injection and Tendon Stressing | North Texas Foundation Field Manual — published by North Texas Foundation Field Manual
Thing

Foundation Repair Permits in DFW Cities

Plano, McKinney, Fort Worth and others require permits and engineer documents. A missing file is a question.

Relations:

  • PART_OF → Repair and records

A foundation repair permit is a city's record that a repair was planned, reviewed and closed. In the Dallas-Fort Worth area, cities generally require a permit for foundation repair and ask for documents prepared by a licensed professional engineer. The details vary, which is why a buyer should check the specific city. Plano, McKinney, Fort Worth and others require permits and engineer documents. A missing file is a question.

Foundation Repair Permits in DFW Cities | North Texas Foundation Field Manual — published by North Texas Foundation Field Manual
Thing

Repair Records and Warranty Transfers

Engineer letters, permits, pier plans and the warranty's transfer terms. Texas does not license repair contractors.

Relations:

  • PART_OF → Repair and records

Foundation repair leaves a paper trail when it is done properly: an engineer's evaluation, a repair design, a pier plan, a city permit, elevation readings before and after, an engineer's letter at completion, and a contractor's warranty. Together these tell a buyer what problem was found, what was done about it, whether the city closed the permit, and what protection remains. Engineer letters, permits, pier plans and the warranty's transfer terms. Texas does not license repair contractors.

Repair Records and Warranty Transfers | North Texas Foundation Field Manual — published by North Texas Foundation Field Manual
Taxonomy

Soils and Slabs in North Texas

The ground under Dallas-Fort Worth houses and the foundations built on it: expansive clay, plasticity index, potential vertical rise, trees, drainage, post-tensioned slabs, conventional slabs and pier and beam.

Relations:

  • INCLUDES → Expansive Clay and the Blackland Prairie
  • INCLUDES → Plasticity Index (PI)
  • INCLUDES → Potential Vertical Rise (PVR)
  • INCLUDES → Trees and Soil Moisture
  • INCLUDES → Grading and Drainage
  • INCLUDES → Post-Tensioned Slab Foundations
  • INCLUDES → Conventionally Reinforced Slab Foundations
  • INCLUDES → Pier and Beam Foundations

The ground under Dallas-Fort Worth houses and the foundations built on it: expansive clay, plasticity index, potential vertical rise, trees, drainage, post-tensioned slabs, conventional slabs and pier and beam.

Soils and Slabs: North Texas Clay and Foundation Types | dfwhomeinspection.com — published by North Texas Foundation Field Manual
Taxonomy

Foundation Evaluation and Repair in North Texas

How North Texas foundations are judged and repaired: the TREC inspector opinion, engineering investigation levels, elevation surveys, deflection and tilt, distress, underpinning, grouting, city permits and repair records.

Relations:

  • INCLUDES → The Inspector's Foundation Opinion
  • INCLUDES → Engineering Investigation Levels A, B and C
  • INCLUDES → Floor Elevation Surveys
  • INCLUDES → Deflection and Tilt Criteria
  • INCLUDES → Distress Indicators
  • INCLUDES → Underpinning Piles and Piers
  • INCLUDES → Grouting, Crack Injection and Tendon Stressing
  • INCLUDES → Foundation Repair Permits in DFW Cities
  • INCLUDES → Repair Records and Warranty Transfers

How North Texas foundations are judged and repaired: the TREC inspector opinion, engineering investigation levels, elevation surveys, deflection and tilt, distress, underpinning, grouting, city permits and repair records.

Foundation Evaluation and Repair in North Texas | dfwhomeinspection.com — published by North Texas Foundation Field Manual
Taxonomy

Soils and site

Expansive clay, plasticity index, potential vertical rise, trees and drainage: the ground a North Texas foundation sits on: one of the four families of sheets in the North Texas Foundation Field Manual.

Relations:

  • INCLUDES → Expansive Clay and the Blackland Prairie
  • INCLUDES → Plasticity Index (PI)
  • INCLUDES → Potential Vertical Rise (PVR)
  • INCLUDES → Trees and Soil Moisture
  • INCLUDES → Grading and Drainage

Expansive clay, plasticity index, potential vertical rise, trees and drainage: the ground a North Texas foundation sits on: one of the four families of sheets in the North Texas Foundation Field Manual.

The Four Sheet Families: Soil, Types, Evaluation, Repair | dfwhomeinspection.com — published by North Texas Foundation Field Manual
Taxonomy

Foundation types

Post-tensioned slabs, conventionally reinforced slabs and pier and beam foundations: one of the four families of sheets in the North Texas Foundation Field Manual.

Relations:

  • INCLUDES → Post-Tensioned Slab Foundations
  • INCLUDES → Conventionally Reinforced Slab Foundations
  • INCLUDES → Pier and Beam Foundations

Post-tensioned slabs, conventionally reinforced slabs and pier and beam foundations: one of the four families of sheets in the North Texas Foundation Field Manual.

The Four Sheet Families: Soil, Types, Evaluation, Repair | dfwhomeinspection.com — published by North Texas Foundation Field Manual
Taxonomy

Evaluation

The inspector's opinion, the engineer's investigation levels, elevation surveys, deflection and tilt, and distress signs: one of the four families of sheets in the North Texas Foundation Field Manual.

Relations:

  • INCLUDES → The Inspector's Foundation Opinion
  • INCLUDES → Engineering Investigation Levels A, B and C
  • INCLUDES → Floor Elevation Surveys
  • INCLUDES → Deflection and Tilt Criteria
  • INCLUDES → Distress Indicators

The inspector's opinion, the engineer's investigation levels, elevation surveys, deflection and tilt, and distress signs: one of the four families of sheets in the North Texas Foundation Field Manual.

The Four Sheet Families: Soil, Types, Evaluation, Repair | dfwhomeinspection.com — published by North Texas Foundation Field Manual
Taxonomy

Repair and records

Underpinning, grouting and tendon work, city permits, and the records and warranties that follow a repair: one of the four families of sheets in the North Texas Foundation Field Manual.

Relations:

  • INCLUDES → Underpinning Piles and Piers
  • INCLUDES → Grouting, Crack Injection and Tendon Stressing
  • INCLUDES → Foundation Repair Permits in DFW Cities
  • INCLUDES → Repair Records and Warranty Transfers

Underpinning, grouting and tendon work, city permits, and the records and warranties that follow a repair: one of the four families of sheets in the North Texas Foundation Field Manual.

The Four Sheet Families: Soil, Types, Evaluation, Repair | dfwhomeinspection.com — published by North Texas Foundation Field Manual
Document

North Texas Foundation Field Manual: Soils, Slabs, Repair

How Dallas-Fort Worth foundations are built for expansive clay, judged by inspectors and engineers, repaired, and permitted city by city.

Much of the Metroplex sits on expansive Blackland clay that swells when wet and shrinks when dry. Builders design slabs for it, inspectors and engineers judge how a foundation is performing on it, and cities permit the repairs. This manual sets out each step in 17 numbered sheets and 9 guides, with the engineering guidelines, state rules and city requirements behind every statement.

North Texas Foundation Field Manual: Soils, Slabs, Repair — published by North Texas Foundation Field Manual
Document

Foundation Field Manual: All 17 Sheets

All 17 sheets of the North Texas Foundation Field Manual: soil and site, foundation types, evaluation, and repair and records, each labeled.

This register lists every sheet in the manual, numbered the way an engineer numbers a drawing set. S sheets cover soil and site, F sheets the foundation types, E sheets evaluation, and R sheets repair and records. Each sheet carries one label, stated before anything else: read first, depends on the house, or often misread.

Foundation Field Manual: All 17 Sheets — published by North Texas Foundation Field Manual
Document

Guides to North Texas Foundations and Repair

Guides on DFW foundations: Blackland clay, slab design, seasonal movement, inspector and engineer opinions, surveys, permits and repair records.

The sheets define the parts. These guides follow one question at a time through them, in three sections: how the ground moves under a house, how a foundation is measured and judged, and how a repair is designed, permitted and documented. Each section opens with an overview.

Guides to North Texas Foundations and Repair — published by North Texas Foundation Field Manual
Document

How North Texas Ground Moves Under a Foundation

Why DFW foundations move: expansive Blackland clay, how slabs are engineered for it, and the seasonal wet-dry cycle that drives most distress.

Blackland clay and the geology behind it, how slabs are engineered for expansive soil, and the seasonal wet and dry cycle that drives most movement.

How North Texas Ground Moves Under a Foundation — published by North Texas Foundation Field Manual
Document

Measuring and Judging a North Texas Foundation

How Texas foundations are evaluated: the TREC inspector's opinion, engineering investigation levels, elevation surveys, deflection, tilt and distress.

Where the inspector's opinion ends and the engineer's begins, how to read an elevation survey, and when movement becomes a defect.

Measuring and Judging a North Texas Foundation — published by North Texas Foundation Field Manual
Document

Foundation Repair, Permits and Records in DFW

How DFW foundation repair works: underpinning, grouting, tendon work, city permits, engineer letters, warranties and the records buyers should collect.

Foundation repair permits city by city, what an engineer's letter should contain, and what owners should do after a repair.

Foundation Repair, Permits and Records in DFW — published by North Texas Foundation Field Manual
Document

Blackland Clay and DFW Geology for Homeowners

How the Blackland Prairie's expansive clays formed, why they swell and shrink, how they vary across DFW, and what that means for houses built on them.

The soil under much of Dallas-Fort Worth formed from ancient sea-floor clays and marls. Its chemistry, not bad luck, is why North Texas houses move.

Blackland Clay and DFW Geology for Homeowners — published by North Texas Foundation Field Manual
Document

How Slab Foundations Are Designed for Expansive Clay

How engineers design slabs for expansive clay: PTI DC10.5 for post-tensioned slabs, WRI/CRSI for rebar slabs, and city permit rules.

A slab on North Texas clay is designed for the soil under that lot. Knowing how that design is done tells a buyer what documents to look for and what they mean.

How Slab Foundations Are Designed for Expansive Clay — published by North Texas Foundation Field Manual
Document

Seasonal Foundation Movement and Monitoring

Why North Texas foundations move with the seasons, how movement is monitored, and why guidelines favor non-structural measures first.

A crack that opens in August and closes in March is telling you something. Watching movement over time is often the best way to understand it, and the guidelines say so.

Seasonal Foundation Movement and Monitoring — published by North Texas Foundation Field Manual
Document

Inspector Opinion vs Engineering Opinion on Foundations

How a Texas inspector's foundation opinion differs from an engineer's evaluation, where the line falls, and when a buyer should call each.

Texas asks home inspectors to say whether a foundation is performing and asks engineers to say why and what to do. Knowing the line tells a buyer which report answers which question.

Inspector Opinion vs Engineering Opinion on Foundations — published by North Texas Foundation Field Manual
Document

Interpreting a Foundation Elevation Survey

How to read a floor elevation survey: the reference point, contour patterns, floor coverings, built-in unevenness and comparing surveys.

An elevation survey turns a floor into numbers. Read well, it shows patterns an engineer can explain. Read badly, it makes ordinary unevenness look like failure.

Interpreting a Foundation Elevation Survey — published by North Texas Foundation Field Manual
Document

When Foundation Movement Becomes a Defect

How Texas inspectors and engineers separate normal foundation movement on clay from adverse performance: differential settlement and tolerances.

Every foundation on North Texas clay moves. The question inspectors and engineers answer is whether it moves too much, too unevenly, or in a way that harms the house.

When Foundation Movement Becomes a Defect | dfwhomeinspection.com — published by North Texas Foundation Field Manual
Document

Foundation Repair Permits Across Dallas-Fort Worth

A city-by-city look at foundation repair permits in Dallas-Fort Worth: engineer documents, inspections, and how buyers search records.

The Metroplex is dozens of cities, each with its own permit rules. For foundation repair, most agree on two things: a permit, and an engineer's sealed design.

Foundation Repair Permits Across Dallas-Fort Worth — published by North Texas Foundation Field Manual
Document

What a Foundation Engineer's Letter Should Contain

What a useful foundation engineer's report or repair letter includes, from investigation level and measurements to seal, plus red flags.

Buyers in North Texas often hold an engineer's letter, from their own engineer or a seller's past repair. A good one shows its work. A thin one may say less than it seems.

What a Foundation Engineer's Letter Should Contain — published by North Texas Foundation Field Manual
Document

After Foundation Repair: Maintenance and Monitoring

What North Texas owners should do after foundation repair: drainage, moisture, monitoring, plumbing checks, warranty upkeep and records.

Foundation repair is a point in a house's history, not the end of it. What the owner does afterward decides how the repair performs and what the next buyer can learn.

After Foundation Repair: Maintenance and Monitoring — published by North Texas Foundation Field Manual
Document

About North Texas Foundation Field Manual

Who publishes the North Texas Foundation Field Manual, what it rests on, and how its sheets are researched, sourced and dated.

North Texas Foundation Field Manual is a reference on one subject: the foundations of houses in Dallas-Fort Worth and the soil they sit on. It covers expansive Blackland clay and the numbers engineers use to describe it; post-tensioned slabs, conventionally reinforced slabs and pier and beam foundations; how a Texas home inspector and a licensed professional engineer each evaluate a foundation; the signs of distress they look for; the main repair methods; and how cities across the Metroplex permit foundation repair.

About North Texas Foundation Field Manual — published by North Texas Foundation Field Manual
Document

Contact

Send a correction or a general question about the manual. No reports reviewed, no referrals, no advice on a particular house.

This page is for corrections to the manual and for general questions about how North Texas foundations are evaluated and repaired. It is not a way to reach an inspector, an engineer or a repair company, and no one here will read, interpret or review an inspection report, an engineer's letter, an elevation survey, a repair estimate or a warranty for a particular house.

Contact | North Texas Foundation Field Manual — published by North Texas Foundation Field Manual