LabelOften misread
Revised

Not every foundation repair is a pier. Engineers also fill voids, inject cracks and restress tendons. Each answers a different problem, and some can work against piers.

What it is

The ASCE Texas Section guidelines list several slab remedial measures besides underpinning: grouting, mudjacking, crack injecting, tendon stressing, and partial demolition and reconstruction. Each addresses something different.

Grouting and mudjacking pump a material beneath a slab through drilled holes. The goal may be to fill voids left by soil loss or erosion, or to raise a sunken area. A manufacturer's comparison of repair options describes slab jacking as drilling or coring holes and pumping fluid under pressure to float or raise the slab. Polyurethane foam is a newer variant.

Crack injection fills cracks in the concrete, typically with epoxy. The guidelines note that injecting cracks about 1/32 inch and larger restores stiffness to the slab, while sealants may be enough if the goal is only to limit moisture or insects.

Tendon stressing applies to post-tensioned slabs. When testing shows tendon forces below original design or code requirements, restressing may restore the prestress. The guidelines say stressing should follow any elevation adjustments and epoxy crack injection.

When they conflict

The guidelines warn that grouting or mudjacking should not be performed beneath underpinned foundations if expected soil swelling could damage the structure. Filling the space under a slab that is now supported on piers removes room for the clay to swell, which can push the slab up against its supports. That is a strong reason to want one engineer's plan for the whole repair rather than separate jobs from separate contractors.

Where tendons need care

Restressing, repairing or replacing a tendon involves energy stored in steel. Unbonded tendons lose effectiveness over their full length when cut, and a cut stressed tendon can release violently. Locating tendons before any coring or drilling, including drilling for grout injection, is essential.

What a buyer should look for

Patched drill holes in a garage slab or patio can mean mudjacking or grout injection was done. Epoxy lines along cracks mean injection. Repaired anchor pockets at a slab edge may mean tendon work. Ask what was done, why, and who designed it. A city permit file or engineer letter should describe it; see repair records and warranties.

Who decides

An engineer should specify these measures as part of an overall repair plan, often after a Level C investigation that includes testing. Post-tensioning cable testing is one of the tests the guidelines list at that level.

Common misreadings

"Mudjacking is a cheaper pier." It addresses voids and lifting, not deep support.

"Seal the crack and the problem is solved." Sealing limits moisture; injection restores stiffness; neither stops movement.

"Grout under a pier-supported slab is extra insurance." The guidelines warn it can cause damage.

Field notes

Count and photograph patched holes and injected cracks during a walk-through. They are evidence of history worth asking about.

Sequencing a repair plan

Because these measures interact, the order matters. The ASCE Texas Section guidelines place tendon stressing after any elevation adjustment and crack injection, and they warn against grouting under a slab that is now on piers where swelling clay could push it up. A single engineer's plan sets that sequence. A buyer who sees evidence of several separate jobs on one slab, done at different times by different contractors, should ask whether anyone looked at the whole foundation, and whether a later repair may have worked against an earlier one.

Where the facts come from

ASCE Texas Section Guidelines for the Evaluation and Repair of Residential Foundations, Version 3; geoengineer.org summary of a residential repair options comparison; post-tensioning safety guidance.

Short answers

What is mudjacking?

Pumping material under a slab through drilled holes to fill voids or raise it.

Can mudjacking be combined with piers?

The guidelines warn against grouting beneath underpinned slabs where soil swelling could damage the structure.

Should I seal or inject a slab crack?

Injection restores stiffness; sealing limits moisture and insects. An engineer can say which is needed.

What is tendon restressing?

Retensioning post-tensioned tendons when testing shows force below design.