North Texas Foundation Field Manual logo — a slab and pier in section inside a drawing title blockNorth Texas Foundation Field ManualSoils, slabs, evaluation and repair in Dallas-Fort Worth
SheetS-02
Title

Plasticity Index (PI)

FamilySoils and site
LabelDepends on the house
Revised

The plasticity index is the number a soils report uses to describe how much a clay can change. Higher PI generally means more potential to swell and shrink.

What it is

The plasticity index, or PI, is a laboratory value that describes how a fine-grained soil behaves as its water content changes. It comes from the Atterberg limits. The liquid limit is the water content at which a soil starts to flow like a liquid; the plastic limit is the water content at which it stops being moldable and begins to crumble. The plasticity index is the difference between the two.

A soil with a wide range between those limits stays plastic over a broad span of moisture. In practice, clays with high plasticity indexes tend to be the ones that swell and shrink the most. The Texas Department of Transportation describes the plasticity index as correlated with numerous engineering properties, which is why it appears in nearly every soils investigation in the region.

Why it matters on DFW clay

Engineers designing a slab for a North Texas lot need a way to describe how active the soil is. PI is one of the simplest. It is also the basis of TxDOT's method for estimating potential vertical rise, which correlates PI to swelling. Foundation design standards for slabs on expansive soil, such as the Post-Tensioning Institute's DC10.5, use soil properties derived from laboratory testing to set design values.

For a buyer, PI usually appears in two places: a geotechnical report prepared for a subdivision or a lot, and an engineer's foundation design letter that cites the soil conditions. Many DFW cities ask for an engineer's letter that states the soil information used to design a new house's foundation.

What it tells you, and what it does not

A high PI tells you the soil has a high capacity to change volume with moisture. It does not tell you how much moisture will change under a particular house, how the foundation was designed, or how the house has performed. A house on very active clay can perform well if it was designed for that soil and its moisture is kept reasonably even. A house on less active soil can still move if a leak or poor drainage concentrates water in one place.

PI is also a sample value. Soils vary with depth and across a lot. One boring describes one spot.

Who decides

Geotechnical engineers sample and test soil and report PI. Structural engineers use those results to design foundations. When a house is being evaluated, an engineer may order soil testing as part of what the ASCE Texas Section guidelines call a Level C investigation. An inspector does not test soil.

Common misreadings

"A high PI means the house is failing." It describes the soil, not the house.

"Low PI means no movement." Concentrated moisture changes can move any clay.

"The report from the subdivision applies to my lot exactly." Soils vary; ask what was tested where.

Field notes

If a seller or builder can provide the geotechnical report or the foundation design letter, keep it with the house records. Look for the PI values, the depths sampled, and the design method the engineer used. Those documents are the starting point for any later evaluation.

Where a buyer will see it

The plasticity index appears in geotechnical reports prepared for subdivisions and for individual lots, and sometimes in the foundation engineer's design letter in the city permit file. It may be reported as a range across several borings. A buyer does not need to calculate anything; it is enough to know that higher values describe more active clay, that the slab was designed with those values in mind, and that the house's actual behavior is the better guide to its condition.

Where the facts come from

TxDOT Pavement Design Manual, Subsurface Exploration; University of Texas at Austin training material on the PVR method; PTI DC10.5; ASCE Texas Section residential foundation guidelines, Version 3.

Short answers

What is a high plasticity index?

The term is relative. Engineers interpret PI along with other test results and local experience. A higher PI generally indicates more potential to swell and shrink.

Does an inspector test PI?

No. PI comes from laboratory testing ordered by an engineer.

Where would I find PI for a house?

In a geotechnical report for the lot or subdivision, or cited in the engineer's foundation design letter.

Does PI predict foundation problems?

No. It describes the soil. Performance depends on design, moisture and maintenance.