Overview
The numbering is not decoration. A drawing set is read in a known order, and so is a foundation question. The soil comes first, because expansive clay is the reason North Texas foundations move at all. The foundation type comes next, because a post-tensioned slab, a conventionally reinforced slab and a pier and beam floor respond to the same clay in different ways. Evaluation follows, because the inspector's opinion and the engineer's measurements are how anyone decides whether movement is normal. Repair and records come last, because a repair only makes sense once the cause has been named. Those four prefixes are also the four families the sheets are grouped into for browsing.
How to read the labels
The label describes the subject of the sheet, not any house. Read first marks the sheets that frame everything else, such as expansive clay, the TREC foundation opinion and the city permit rules. Depends on the house marks subjects whose importance turns on the particular property: the plasticity index of its soil, its trees, whether it sits on pier and beam, whether it has been underpinned. Often misread marks subjects that are regularly quoted with more confidence than they deserve: potential vertical rise, investigation levels, deflection and tilt numbers, and grouting.
What every sheet contains
Every sheet answers the same questions in the same order. It says what the subject is, with technical terms defined where they first appear. It sets out the common misreadings, because most foundation arguments start with one. It gives field notes for a buyer, owner or agent looking at a real house. It names the sources, which are engineering guidelines, state rules, city documents and published research rather than other websites. It closes with short answers to the questions people actually ask. The margin of each sheet carries five notes that summarize it, and a list of the other sheets in the same family.
Where the manual's authority comes from
The engineering content rests mainly on the ASCE Texas Section's guidelines for the evaluation and repair of residential foundations, now in their third version, and on the Post-Tensioning Institute's design literature. The inspection content rests on the Texas Real Estate Commission's standards of practice and its 2025 guidance on foundation opinions, and on the Texas Board of Professional Engineers' advisory opinion on where inspection ends and engineering begins. The permit content comes from the cities themselves. Soil descriptions come from the U.S. Natural Resources Conservation Service.
Citing a sheet
Each sheet keeps its number. A buyer, agent or inspector who wants to point someone to a definition can cite the number and title, such as sheet E-02 for investigation levels or R-03 for repair permits, and the reference will still resolve after the sheet is revised. The revision date on the title block shows when the content last changed.
How the sheets relate to the guides
The sheets define the parts. The guides, grouped into three sections, follow a question through several sheets at once: why the ground moves, how a foundation is measured and judged, and how a repair is designed, permitted and documented. Each guide lists the sheets it draws on in its margin, and each sheet links to the guides that use it. A reader can start in either place.
What the manual does not do
It does not evaluate any house, recommend any engineer or repair company, or price any work. Those belong with professionals who can see the property. The manual's job is to make their reports easier to understand and the right questions easier to ask.
| Sheet | Title | Family | Label |
|---|---|---|---|
| S-01 | Expansive Clay and the Blackland Prairie | Soils and site | Read first |
| S-02 | Plasticity Index (PI) | Soils and site | Depends on the house |
| S-03 | Potential Vertical Rise (PVR) | Soils and site | Often misread |
| S-04 | Trees and Soil Moisture | Soils and site | Depends on the house |
| S-05 | Grading and Drainage | Soils and site | Read first |
| F-01 | Post-Tensioned Slab Foundations | Foundation types | Read first |
| F-02 | Conventionally Reinforced Slab Foundations | Foundation types | Depends on the house |
| F-03 | Pier and Beam Foundations | Foundation types | Depends on the house |
| E-01 | The Inspector's Foundation Opinion | Evaluation | Read first |
| E-02 | Engineering Investigation Levels A, B and C | Evaluation | Often misread |
| E-03 | Floor Elevation Surveys | Evaluation | Depends on the house |
| E-04 | Deflection and Tilt Criteria | Evaluation | Often misread |
| E-05 | Distress Indicators | Evaluation | Read first |
| R-01 | Underpinning Piles and Piers | Repair and records | Depends on the house |
| R-02 | Grouting, Crack Injection and Tendon Stressing | Repair and records | Often misread |
| R-03 | Foundation Repair Permits in DFW Cities | Repair and records | Read first |
| R-04 | Repair Records and Warranty Transfers | Repair and records | Depends on the house |